Description
2-A1MP hydrochloride (2-Aminomethyl-1-methylpiperidine) is a highly pure, analytical reference standard and a fascinating member of the chemical class of Piperidine analogues. Due to its unique heterocyclic structure, which contains both a secondary and a tertiary nitrogen atom, 2-A1MP is a key reagent in the chemical researchthe Toxicology and the molecular pharmacology. This standard is essential for laboratories that receptor activities and Structure-activity relationships (SAR) of nitrogen-containing heterocyclic compounds and expand their analytical methods for novel molecules.
The acquisition of this 2-A1MP Standards takes place for strictly scientific purposes only on qualified experts and Accredited research institutions. We guarantee a analytically confirmed purity of 98% of the hydrochloride salt, which is the absolute basis for precise, traceable and reproducible Results in the Chromatography and spectroscopy . Ensuring this purity is critical to avoid false positive or false negative results in forensic analysis. For laboratories that require a 2-A1MP Reference Standard, Piperidine control material or analytical reagents Looking to expand your chemical library, we offer the highest quality and global compliance assurance.
Chemical and Analytical Excellence: Detailed Specifications and Certification
Precise chemical characterization and metrology are the cornerstones of reliable forensic and analytical methods. 2-A1MP must be precisely calibrated against certified standards for validation.
Detailed Chemical Identity and Structure
2-A1MP stands out thanks to its saturated piperidine ring The functional groups – the aminomethyl group and the N-methyl substitution – are of great interest in the field of molecular modeling and Receptor studies.
- Chemical class: Piperidine analogues (heterocyclic amines).
- Nomenclature: 2-Aminomethyl-1-methylpiperidine (often as hydrochloride salt).
- Molecular weight: Crucial for gravimetric standard preparation and calibration of quadrupole mass spectrometers.
- Formulation: Is available as a stable Hydrochloride salt before, what the Durability and Solubility Optimized for analytical assays in aqueous and polar solvents (methanol, acetonitrile).
- Aggregate state: High purity crystalline powder, optimized for precise gravimetric weighing according to ISO 17025 regulations.
Guaranteed purity and traceability for GLP/ISO
We guarantee a purity of 98% Certain, confirmed by a rigorous, multi-analytical testing process to ensure compliance with the highest analytical standards.
- Confirmation of purity: Quantification is primarily carried out using HPLC (High-Performance Liquid Chromatography). Molecular identity is additionally determined by means of GC/MS and/or LC-MS/MS confirmed.
- Certificate of Analysis (CoA): A detailed CoA is included with every delivery, containing spectral data, purity assessment, and Traceability of the batch. This document is required for the GLP-compliant documentation and the legal usability of the data is absolutely essential.
- Batch consistency: The minimum Batch variability is ensured by strict controls, which is important for the Long-term validation of methods is crucial.
Central fields of application in research and analytics
2-A1MP hydrochloride is a fundamental reagent for laboratories dealing with the Development of analytical methods and the molecular pharmacology novel substances.
Pharmacological and receptor studies (molecular modeling)
- Receptor affinity: Investigation of the Attachment affinity on various neuroreceptor subtypes to determine the molecular action profile and predict toxicity.
- Structure-activity relationships (SAR): 2-A1MP serves as the basic structure for the systematic investigation of how substitutions on the piperidine ring affect biological activity.
- Molecular modeling: The connection is established for in silico-Studies used to model the geometric fit in hypothetical receptor binding sites and derive potential drug candidates.
Analytical method development and toxicology
The standard is essential for forensic laboratories to update their databases and expand their methods.
- Method validation: The standard is used for Validation from LC-MS/MS and GC-MS Methods for Identification and Quantification novel piperidine analogues. This includes the determination of the Sensitivity (LOD/LOQ) and the Matrix effects.
- Database reference: 2-A1MP serves as analytical reference point for the creation and maintenance of analytical spectral libraries, enabling the rapid identification of unknown samples in forensic cases.
- Metabolism research: Initial studies on Metabolite identification are necessary to understand the degradation profile of the substance and to extend the detection windows in toxicology.
Legal framework and laboratory safety (global compliance)
The acquisition and handling of this controlled research chemicals are subject to the strictest regulations and are reserved exclusively for scientific research.
Regulatory compliance
Since 2-A1MP is a novel compound, compliance with national laws (e.g. NpSG in Germany) and international control mechanisms (e.g., analogues of the CSA in the USA) by the buyer be guaranteed.
- Exclusively research: Sales are strictly limited to the Analysis and research in authorized scientific institutions limited.
- Buyer obligation: The buyer assumes full responsibility for compliance with all local and international laws regarding the import, possession, and use of controlled chemicals. The duty to provide evidence The acquiring laboratory is responsible for compliance with the regulatory framework.
Safety protocols and storage
Strict compliance with the Material Safety Data Sheet (MSDS) is mandatory.
- PSA: Lab coat, safety goggles and chemical resistant Gloves are obligatory.
- Working environment: Powder handling must be carried out under certified fume cupboard systems take place.
- Storage: Cool, dry, and protected from light store in order to analytical stability to ensure. The inventory documentation must be carried out in full accordance with laboratory protocols (e.g., SOPs).
Purchase of the 2-A1MP reference standard – your partner for analytical excellence
We offer 2-A1MP hydrochloride in analytically relevant quantities: 100 mg (reference sample), 500 mg and 1 g.
Mandatory order requirements:
- Proof of the Authorization of the research institution.
- Written confirmation that the substance exclusively for analytical reference purposes is used.
- Recognition of the Limitations of liability and the MSDS.
For secure, legally compliant and fast ordering of your 2-A1MP Reference Standards to guarantee the Validity of your analytical methods, please contact us directly.






Reviews
There are no reviews yet.